Spray Bar and Controlled Pressure Testing

Spray Bar and Controlled Pressure Testing

RAM’s Spray Bar and Controlled Pressure Testing: RAM Consultancy often undertakes Spray Bar and Controlled Pressure Testing, a UKAS certified procedure. The service confirms the water tightness of curtain walling and cladding systems by directing concentrated water sprays to specific areas of the building envelope. A distance of 250mm is maintained between the face of elevation and the spray nozzle. The apparatus discharges water at a flow rate of 5 litres a minute per metre at a pressure of 2 to 3 bar through a calibrated control valve and gauge, sustained for a 30 minute continuous test.

Spray Bar Testing is suitable for open-jointed systems such as rainscreen cladding, unsealed patent glazing, opening lights or doors and smoke vents.

Controlled Pressure Testing is intended for testing permanently sealed joints of the installed cladding system to ensure that the performance of the system has not been reduced by the fabrication and installation.

  • Confirm Water tightness of Windows/Cladding
  • Simulates the Leak for discovery
  • 2 Specialist RAM Engineers Required

Please contact us if you are need of any assistance.

Contact UsDownload PDF Service Sheet

Service Video


Service Benefits

Spray Bar TestingAccurately confirms the water tightness of windows and cladding.

Spray Bar TestingSimulates the leak allowing for easy discovery & detection.

Roof Leak DetectionSuitable for open-jointed systems including cladding, glazing, lighting, doors and vents.

Building Leak DectectionOperated by a minimum of two skilfully trained RAM Consultants.

Spray Bar and Hose Testing
Spray Bar and Hose Testing
Spray Bar and Hose Testing
Spray Bar and Hose Testing

Spray Bar and Hose Testing

Spray Bar and Controlled Pressure Testing

Controlled Pressure Testing is intended for testing permanently sealed joints of the installed cladding system to ensure that the performance of the system has not been reduced by the fabrication and installation. We’ve used this method to identify leaks in cladding, curtain walling, roofs and skylights, and our expert RAM engineers will carry out a survey to suggest repairs if action is required.

Our Spray Bar and Controlled Pressure tests will deliver the following:

  • Confirm water tightness of windows/cladding
  • Simulate the leak for swift discovery
  • Expert Advice from 2 specialist RAM engineers (required)

We’ve helped a comprehensive range of property owners detect leaks quickly, saving them significant sums on repairs. Our rigorous tests are carried out the latest CWCT standards, whilst they’re very cost-effective and suitable for small and large areas. We’ve carried out tests on a broad range of commercial and residential properties, and no surface is too large for our dedicated team. Whether you’re looking to test facades, windows, cladding or entire building envelopes, RAM can help, and you can find out more by getting in touch with us today.